T4Q1 Card

Inquiry Now
Get A Quote
Specifications
Function:
Occupied Slots
Description:
1/4 Slots,shown In Name 1~8 Slot
Function:
Client-side Interface
Description:
Supports 4 Pluggable QSFP28 100G Modules
Function:
Line-side Interface
Description:
Supports 1 Pluggable 400G CFP2 DCO Coherent Module
Function:
Service Type
Description:
100GE
Function:
Service Mapping Path
Description:
4*100G Client To 1*400G Line Mode: . 100G<->ODU4<->ODUC4<->OTUC4
Function:
Line-side Modulation Format
Description:
400G: 16QAM/16QAM-PCS/QPSK
Function:
WDM Technology
Description:
Support DWDM: C-band 50GHz 96 Waves Tunable
Function:
FEC Technology
Description:
Support OFEC
Function:
Client-side Ethernet RMON Monitoring Function
Description:
Support
Function:
Client-side Automatic Laser Shutdown (ALS)
Function:
Local Fault
Description:
Supports Downstream Insertion Of Local Fault From The Client Side In Case Of Ethernet Input Loss Or WDM Side Failure. Supports Transparent Transmission Of Local Fault And Remote Fault.
Function:
Loop
Function:
Time Delay Measurement
Function:
Line-side Protection Function
Description:
When Switching Over With The Optical Protection Card, The Switchover Must Be Completed Within 50ms.
Product Description
Typical Applications Technical Specifications Related Euipment Related Download

T4Q1 Card

Technical specifications

Function Description
Occupied Slots

1/4 slots,shown in name 1~8 slot

Client-side Interface

Supports 4 pluggable QSFP28 100G modules

Line-side Interface Supports 1 pluggable 400G CFP2 DCO coherent module
Service Type 100GE
Service Mapping Path

4*100G client to 1*400G line mode:

. 100G<->ODU4<->ODUC4<->OTUC4

Line-side Modulation Format 400G: 16QAM/16QAM-PCS/QPSK
WDM Technology Support DWDM: C-band 50GHz 96 waves tunable
FEC Technology

Support oFEC

Client-side Ethernet RMON Monitoring Function Support
Client-side Automatic Laser Shutdown (ALS) Support
Local Fault Supports downstream insertion of Local Fault from the client side in case of Ethernet input loss or WDM side failure. Supports transparent transmission of Local Fault and Remote Fault.
Loop Support
Time Delay Measurement Support
Line-side Protection Function When switching over with the optical protection card, the switchover must be completed within 50ms.

Related Euipment

T4Q1 Card
DCI-BOX Platform
T4Q1 Card
DCI Integrated WDM System
T4Q1 Card
Optical Layer Cards
T4Q1 Card
Electrical Layer Cards
T4Q1 Card
Chassis Cards
T4Q1 Card

DCI5800-1A

DCI5800 is an industry-leading innovative DCI OTN transmission platform launched by ‌‌ISEELINK‌‌. DCI5800 has the characteristics of small size, large capacity service access, long distance transmission, Web GUI simple and convenient operation and management, reliable operation and energy saving and emission reduction, which effectively meets the needs of long-distance and large bandwidth user data center interconnection transmission. The DCI5800 features a modular design that enables both optical-electrical decoupling for cost reduction and integrated management within the same chassis. With SDN capabilities, it creates an intelligent and open network architecture. The system supports the YANG model interface based on the NetConf/YANG protocol, while also offering multiple management methods including Web GUI, CLI, NetConf,and SNMP for streamlined operations.

Explore Further
T4Q1 Card

DCI5800-2A

DCI5800 is an industry-leading innovative DCI OTN transmission platform launched by ‌‌ISEELINK‌‌. DCI5800 has the characteristics of small size, large capacity service access, long distance transmission, Web GUI simple and convenient operation and management, reliable operation and energy saving and emission reduction, which effectively meets the needs of long-distance and large bandwidth user data center interconnection transmission. The DCI5800 features a modular design that enables both optical-electrical decoupling for cost reduction and integrated management within the same chassis. With SDN capabilities, it creates an intelligent and open network architecture. The system supports the YANG model interface based on the NetConf/YANG protocol, while also offering multiple management methods including Web GUI, CLI, NetConf,and SNMP for streamlined operations.

Explore Further
T4Q1 Card

DCI3100

The DCI3100 integrated wavelength division equipment is developed by ‌‌ISEELINK‌‌ for data center interconnection (DCI) scenarios. It has the outstanding characteristics of large capacity, small size, low energy consumption and high cost performance.Housed in standard 1U chassis, this device supports max 1.6T (16*100G) capacity and can be smoothly expanded to 3.2T capacity through device stacking.Adopting high-density optoelectronic integration technology, OSP3100 avoids complex fiber jumper connections with its unique switch-like design and brings ultimate user experience by its extremely simple installation.

Explore Further
T4Q1 Card

OMD96 Equipment

The passive MUX device for signal splitting operates independently of the sub-frame chassis and can be installed in a standard 19-inch data cabinet, with a height of 1U.

Explore Further
T4Q1 Card

OMD48 Equipment

The passive MUX device for signal splitting operates independently of the sub-frame chassis and can be installed in a standard 19-inch data cabinet, with a height of 1U.

Explore Further
T4Q1 Card

OLA Card

The Optica Linel Amplifier Module delivers a versatile, low-noise solution for erbium-doped fiber amplifiers (EDFA). This compact module operates with constant gain (Automatic Gain Control, AGC) and constant output power (Automatic Power Control, APC), featuring a highly integrated design. The large-format module supports dual amplifiers with two independent gain units, the card occupies only 1/4 standard slot capacity.

Explore Further
T4Q1 Card

OPA Card

The Optical Pre Amplifier Module delivers a versatile, low-noise solution for erbium-doped fiber amplifiers (EDFA). This compact module operates with constant gain (Automatic Gain Control, AGC) and constant output power (Automatic Power Control, APC), featuring a highly integrated design. The large-format module supports dual amplifiers with two independent gain units, the card occupies only 1/4 standard slot capacity.

Explore Further
T4Q1 Card

OBA Card

The Optical Boost Amplifier Module delivers a versatile, low-noise solution for erbium-doped fiber amplifiers (EDFA). This compact module operates with constant gain (Automatic Gain Control, AGC) and constant output power (Automatic Power Control, APC), featuring a highly integrated design. The large-format module supports dual amplifiers with two independent gain units, the card occupies only 1/4 standard slot capacity.

Explore Further
T4Q1 Card

M8X2 Card

400G Transponder Card

Explore Further
T4Q1 Card

T8E2 Card

800G Tmux Card

Explore Further
T4Q1 Card

T4Q2 Card

400G Transponder Card

Explore Further
T4Q1 Card

T4Q1 Card

400G Transponder Card

Explore Further
T4Q1 Card

M2H10D1

200G Muxponder Card

Explore Further
T4Q1 Card

4U Chassis Ethernet Interface Card

4U Chassis Ethernet Interface Card

Explore Further
T4Q1 Card

POWER Card

Power Card

Explore Further
T4Q1 Card

2U Chassis Ethernet Interface Card

U Chassis Ethernet Interface Card

Explore Further
T4Q1 Card

2U/4U Chassis FAN Card

2U/4U Chassis FAN Card

Explore Further
T4Q1 Card

2U/4U Chassis NMU Card

2U/4U Chassis NMU Card

Explore Further

Related Resources

T4Q1 Card T4Q1 Card

‌‌ISEELINK‌‌ DCI5800 Product Specifications

PDF - 5.53 MB - Updated on Wednesday, March 25, 2026

T4Q1 Card
Related Products
Send An Inquiry