M2H10D1

Inquiry Now
Get A Quote
Specifications
Function:
Occupied Slots
Description:
1/2 Slots,shown In Name 2/4/6/8 Slot
Function:
Client-side Interface
Description:
Supports 2 Pluggable QSFP28 100G Modules; Supports 1 Pluggable QSFP+ 40G Modules; Supports 10 Pluggable SFP+ 10G Modules
Function:
Line-side Interface
Description:
Supports 1 Pluggable 200G CFP2 DCO Coherent Module
Function:
Service Type
Description:
10GE/OTU2/STM-64/10GE WAN/40GE/100GE/100GE FlexE (Unware Mode)/OTU4
Function:
Service Mapping Path
Description:
2*100G Client To 1*200G Line Mode: 100G<-> ODU4<-> ODUC2<-> OTUC2; OTU4<-> ODU4<-> ODUC2<-> OTUC; 1*100G + 10*10G Client To 1*200G Line Mode: 100G<-> ODU4<-> ODUC2<-> OTUC2; OTU4<-> ODU4<-> ODUC2<-> OTUC2; 10G <->ODU2<->ODU4<-> ODUC2<-> OTUC2; STM64 <-> OD
Function:
Line-side Modulation Format
Description:
200G: 16QAM / QPSK
Function:
Line-side Protection Function
Description:
When Switching Over With The Optical Protection Card, The Switchover Must Be Completed Within 50ms.
Function:
Local Fault
Description:
Supports Downstream Insertion Of Local Fault From The Client Side In Case Of Ethernet Input Loss Or WDM Side Failure. Supports Transparent Transmission Of Local Fault And Remote Fault.
Product Description
Typical Applications Technical Specifications Related Euipment Related Download

M2H10D1

Technical specifications

Function Description
Occupied Slots

1/2 slots,shown in name 2/4/6/8 slot

Client-side Interface

Supports 2 pluggable QSFP28 100G modules

Supports 1 pluggable QSFP+ 40G modules

Supports 10 pluggable SFP+ 10G modules

Line-side Interface Supports 1 pluggable 200G CFP2 DCO coherent module
Service Type 10GE/OTU2/STM-64/10GE WAN/40GE/100GE/100GE FlexE (Unware mode)/OTU4
Service Mapping Path

2*100G client to 1*200G line mode:

. 100G<-> ODU4<-> ODUC2<-> OTUC2

. OTU4<-> ODU4<-> ODUC2<-> OTUC

1*100G + 10*10G client to 1*200G line mode:

. 100G<-> ODU4<-> ODUC2<-> OTUC2

. OTU4<-> ODU4<-> ODUC2<-> OTUC2

. 10G <->ODU2<->ODU4<-> ODUC2<-> OTUC2

. STM64 <-> ODU2 <-> ODU4<-> ODUC2<-> OTUC2

. OTU2 <-> ODU2<-> ODU4<-> ODUC2<-> OTUC2

1*40G + 10*10G client to 1*200G line mode:

. 40G<-> ODU3<-> ODU4<->ODUC2<-> OTUC2

. 10G <->ODU2<->ODU4<-> ODUC2<-> OTUC2

. STM64 <-> ODU2 <-> ODU4<-> ODUC2<-> OTUC2

. OTU2 <-> ODU2<-> ODU4<-> ODUC2<-> OTUC2

Line-side Modulation Format 200G: 16QAM / QPSK
Line-side Protection Function

When switching over with the optical protection card, the switchover must be completed within 50ms.

Local Fault

Supports downstream insertion of Local Fault from the client side in case of Ethernet input loss or WDM side failure. Supports transparent transmission of Local Fault and Remote Fault.

Related Euipment

M2H10D1
DCI-BOX Platform
M2H10D1
DCI Integrated WDM System
M2H10D1
Optical Layer Cards
M2H10D1
Electrical Layer Cards
M2H10D1
Chassis Cards
M2H10D1

DCI5800-1A

DCI5800 is an industry-leading innovative DCI OTN transmission platform launched by ‌‌ISEELINK‌‌. DCI5800 has the characteristics of small size, large capacity service access, long distance transmission, Web GUI simple and convenient operation and management, reliable operation and energy saving and emission reduction, which effectively meets the needs of long-distance and large bandwidth user data center interconnection transmission. The DCI5800 features a modular design that enables both optical-electrical decoupling for cost reduction and integrated management within the same chassis. With SDN capabilities, it creates an intelligent and open network architecture. The system supports the YANG model interface based on the NetConf/YANG protocol, while also offering multiple management methods including Web GUI, CLI, NetConf,and SNMP for streamlined operations.

Explore Further
M2H10D1

DCI5800-2A

DCI5800 is an industry-leading innovative DCI OTN transmission platform launched by ‌‌ISEELINK‌‌. DCI5800 has the characteristics of small size, large capacity service access, long distance transmission, Web GUI simple and convenient operation and management, reliable operation and energy saving and emission reduction, which effectively meets the needs of long-distance and large bandwidth user data center interconnection transmission. The DCI5800 features a modular design that enables both optical-electrical decoupling for cost reduction and integrated management within the same chassis. With SDN capabilities, it creates an intelligent and open network architecture. The system supports the YANG model interface based on the NetConf/YANG protocol, while also offering multiple management methods including Web GUI, CLI, NetConf,and SNMP for streamlined operations.

Explore Further
M2H10D1

DCI3100

The DCI3100 integrated wavelength division equipment is developed by ‌‌ISEELINK‌‌ for data center interconnection (DCI) scenarios. It has the outstanding characteristics of large capacity, small size, low energy consumption and high cost performance.Housed in standard 1U chassis, this device supports max 1.6T (16*100G) capacity and can be smoothly expanded to 3.2T capacity through device stacking.Adopting high-density optoelectronic integration technology, OSP3100 avoids complex fiber jumper connections with its unique switch-like design and brings ultimate user experience by its extremely simple installation.

Explore Further
M2H10D1

OMD96 Equipment

The passive MUX device for signal splitting operates independently of the sub-frame chassis and can be installed in a standard 19-inch data cabinet, with a height of 1U.

Explore Further
M2H10D1

OMD48 Equipment

The passive MUX device for signal splitting operates independently of the sub-frame chassis and can be installed in a standard 19-inch data cabinet, with a height of 1U.

Explore Further
M2H10D1

OLA Card

The Optica Linel Amplifier Module delivers a versatile, low-noise solution for erbium-doped fiber amplifiers (EDFA). This compact module operates with constant gain (Automatic Gain Control, AGC) and constant output power (Automatic Power Control, APC), featuring a highly integrated design. The large-format module supports dual amplifiers with two independent gain units, the card occupies only 1/4 standard slot capacity.

Explore Further
M2H10D1

OPA Card

The Optical Pre Amplifier Module delivers a versatile, low-noise solution for erbium-doped fiber amplifiers (EDFA). This compact module operates with constant gain (Automatic Gain Control, AGC) and constant output power (Automatic Power Control, APC), featuring a highly integrated design. The large-format module supports dual amplifiers with two independent gain units, the card occupies only 1/4 standard slot capacity.

Explore Further
M2H10D1

OBA Card

The Optical Boost Amplifier Module delivers a versatile, low-noise solution for erbium-doped fiber amplifiers (EDFA). This compact module operates with constant gain (Automatic Gain Control, AGC) and constant output power (Automatic Power Control, APC), featuring a highly integrated design. The large-format module supports dual amplifiers with two independent gain units, the card occupies only 1/4 standard slot capacity.

Explore Further
M2H10D1

M8X2 Card

400G Transponder Card

Explore Further
M2H10D1

T8E2 Card

800G Tmux Card

Explore Further
M2H10D1

T4Q2 Card

400G Transponder Card

Explore Further
M2H10D1

T4Q1 Card

400G Transponder Card

Explore Further
M2H10D1

M2H10D1

200G Muxponder Card

Explore Further
M2H10D1

4U Chassis Ethernet Interface Card

4U Chassis Ethernet Interface Card

Explore Further
M2H10D1

POWER Card

Power Card

Explore Further
M2H10D1

2U Chassis Ethernet Interface Card

U Chassis Ethernet Interface Card

Explore Further
M2H10D1

2U/4U Chassis FAN Card

2U/4U Chassis FAN Card

Explore Further
M2H10D1

2U/4U Chassis NMU Card

2U/4U Chassis NMU Card

Explore Further

Related Resources

M2H10D1 M2H10D1

‌‌ISEELINK‌‌ DCI5800 Product Specifications

PDF - 5.53 MB - Updated on Wednesday, March 25, 2026

M2H10D1
Related Products
Send An Inquiry