OSW1×64 TTL optical fiber switch
Introduction of OSW 1*48 optical fiber switch
Optical switch is a kind of functional component, with the ability of switching optical route. In optical fiber transmission system, it is used for multi-channel fiber monitoring, multi light source/ detector selection, and optical fiber path protection etc. Besides, it is also used in optical fiber test system for optical fiber and its component test, outdoor cable test and multi-spot optical sensors monitoring system.
Product Features of TTL optical switch
·Low Loss and High Reliability
·Parallel Interface (TTL)
·Modularized Design
·Epoxy-free on Optical Path
Specifications
| Parameters |
Unit |
OSW1×64 |
| Insertion Loss |
dB |
≤ 1.2 |
| Wavelength Range |
nm |
850±40 / 1300±40,MM |
1260 ~ 1650 SM |
| Test Wavelength |
nm |
850 / 1300,MM |
1310 / 1550 SM |
| Return Loss |
dB |
MM ≥ 30 SM ≥ 50 |
| Crosstalk |
dB |
≥ 70 |
| PDL |
dB |
≤ 0.05 |
| WDL |
dB |
≤ 0.25 |
| TDL |
dB |
≤ 0.25 |
| Repeatability |
dB |
≤ ±0.05 |
| Durability |
Cycles |
≥ 10 Million |
| Switching Time |
ms |
≤ 10(Sequence switch time of adjacent channel) |
| Optical Power |
mW |
≤500 |
| Operating Temperature |
℃ |
-5 ~ +70 |
| Storage Temperature |
℃ |
-40 ~ +85 |
| Relative Humidity |
% |
5 ~ 95 |
| Dimension |
mm |
150×80×67 |
Pin Configurations
DB-15 male connector
| Pin No. |
Signal Name |
I / O |
Description |
| 2 |
D0 |
Input |
TTL, Channel selection bit 0 |
| 3 |
D1 |
Input |
TTL, Channel selection bit 1 |
| 4 |
D2 |
Input |
TTL, Channel selection bit 2 |
| 5 |
D3 |
Input |
TTL, Channel selection bit 3 |
| 6 |
D4 |
Input |
TTL, Channel selection bit 4 |
| 10 |
D5 |
Input |
TTL, Channel selection bit 5 |
Channel Selection Table
| Max Channel |
Input |
Active Channel |
| /RESET |
D6 |
D5 |
D4 |
D3 |
D2 |
D1 |
D0 |
| N=128 |
0 |
x |
x |
x |
x |
x |
x |
x |
0 reset |
| 1 |
0 |
0 |
0 |
0 |
0 |
0 |
0 |
COM → 1 |
| 0 |
0 |
0 |
0 |
0 |
0 |
1 |
COM → 2 |
| 0 |
0 |
0 |
0 |
0 |
1 |
0 |
COM → 3 |
| … |
… |
… |
… |
… |
… |
… |
… |
| 1 |
1 |
1 |
1 |
1 |
1 |
1 |
COM → 128 |
Timing Diagram

Dimension(DBx male head or female head is defined as the actual mark of the element)
Ø 01: 150×80×67-DB15 (N≤64, DB-15 male)

Ordering Information: 7202-1×64L-T-A-B-C-D-E-F-G
Example:7202-1×64L-T-SM-FS-5-90-12-02M-FA
| A |
B |
C |
D |
E |
F |
G |
| Fiber Type |
Test Wavelength |
Operating Voltage |
Tube Type |
Fiber Length |
Dimension |
Connector |
|
SM: SM, 9/125
M5: MM, 50/125
M6: MM, 62.5/125
X: Others
|
85: 850±40nm
O: O band(1260~1360nm)
C: C band(1530~1565nm)
L: L band(1565~1625nm)
U: U band(1625~1675nm)
FS: 1260~1650nm
|
5:5V |
25: 250um
90: 900um
20: 2mm
30: 3mm
X: Others
|
05: 0.5m±5m
10: 1.0m±5m
12: 1.2m±5m
15: 1.5m±5m
X: Others
|
01: 135×40×32-DB9
02: 135×60×32-DB9
X: Others
x=F:female M:male
|
OO: None
LP: LC/PC
LU: LC/UPC
LA: LC/APC
FP: FC/PC
FU: FC/UPC
FA: FC/APC
SP: SC/PC
SU: SC/UPC
SA: SC/APC
STP: ST/PC
STA: ST/APC
X: Others
|
Packing List
· 1pc optical fiber bypass switch
· 1pc user manual
· 1pc warranty card